ECOLINE 100 – I, II, IV Sensor-controlled gas filling station designed to improve thermal and acoustic properties of insulating glass units by low-loss off-line gas filling with premixed, technical or noble gases (e.g. Argon, SF6, Krypton or Xenon) for I.G. manufacture on a medium scale with up to 600 units per shift, depending on pane dimensions and number of outputs - easy start-up and operation, no external calibration
- application of laminar flow technique for ultralow-loss gas filling
- precise gas-sensing proven in more then 1500 installations worldwide
- reliable operation down to 1.2 bar (15 psi) input pressure
| |
| Function & Design
| Automatic gas filling control to minimize gas losses by on-line gas-sensing
| Internal sensor gauging and automatic self-test routines, no test gas, no external interference
| 1, 2 or 4 independent outputs to reduce cycle time
| Maintenance-free by lifetime-checked components
| Exchange units always on stock for emergency express service
|
Technical Data | ECOLINE | Flow Rate capacity per output
| up to 8L / min. (Ar) | | Number of independent outputs | 1, 2 or 4
| Aditional outputs
| on request
| | Height x Length x Width, Weight | 220mm x 260mm/520mm x 480mm, 8 / 16kg
| Power supply
| 230V ± 10%, 50Hz (or as requested)
| Power input / Stand-by
| max. 62VA / 25 VA
| Further Options
| as requested |
Technische Änderungen vorbehalten. Typical Applications - Reliable all-purpose gas filling station, suitable even for specialities
- Economic ultralow-loss filling of expensive gases (e.g. Krypton, Xenon)
- Initial equipment for small and medium sized manufacturers